Serum Cryptococcal Antigen : Diagnostic Value in the Diagnosis of AIDS-Related Cryptococcal Meningitis

THANIN ASAWA VICHIENJINDA, M.D., F.R.C.P. (T)*, CHITR SITTHI-AMORN, M.D., M.Sc., Ph.D.**, VATCHARIN TANYANONT,M.Sc.**

Affiliation : * Department of Medicine, Maharaj Nakhon Ratchasima Hospital, Nakhon Ratchasima 30000, ** The Collage of Public Health, Chulalongkorn University, Bangkok 10330, Thailand.

Abstract
Rationale: The incidences of HIV-AIDS patients with opportumstic infections of the central nervous system are increasing. Of these, cryptococcal meningitis is the most important and serious. A simple method for the diagnosis of cryptococcal meningitis is needed despite its variable clinical features and the lack of a capacity in most health facilities in Thailand to exclude it from other diseases especially mass lesions in the brain.
Objective : To identify the capability and cut off point of serum cryptococcal antigen for diagnosis and screening of cryptococcal meningitis in HIV-AIDS patients.
Method : One hundred consecutive cases of HIV-AIDS patients suspected of having central nervous system infections were prospectively recruited for the study. The serum of all patients were examined for cryptococcal antigen by latex agglutination test, the Pastorex Cryptococcus manufactured by Sanofi Diagnostic Pasteur, France. If a test was positive, the serum dilution was carried out using 10-fold serial dilution. Every patient went through pre-defined standard investigations to derive at a definite diagnosis. The gold standard for diagnosis of cryptococcal meningitis was the presence of encapsulated yeast forms in the cerebrospinal fluid or a positive culture for cryptococcal neoformans from the cerebrospinal fluid. Result: Of 100 patients enrolled in this study, 58 patients had cryptococcal meningitis and serum cryptococcal antigen was detectable in 60 patients. If the cut-off point for a positive test was when the serum cryptococcal antigen titer was more than zero, then, the sensitivity of the test was 91.4 per cent, the specificity was 83.3 per cent, likelihood ratio if test positive (LR+) was 5.47, likelihood ratio if test negative (LR-) was 0.1, false positive was 16.7 per cent, false negative was 8.6 per cent.
Conclusion : We conclude that serum cryptococcal antigen is a simple and rapid screening method for diagnosis of cryptococcal meningitis.

Keywords : Cryptococcal Meningitis - AIDS-Related - Opportunistic Infection - Diagnosis - Serum Cryptococcal Antigen


All Articles Download


INFORMATION

Contact info

JOURNAL OF THE MEDICAL ASSOCIATION OF THAILAND
4th Floor, Royal Golden Jubilee Building,
2 Soi Soonvijai, New Petchburi road,
Bangkok 10310, Thailand.
Phone: 0-2716-6102, 0-2716-6962
Fax: 0-2314-6305
Email: editor@jmatonline.com

JMed Assoc Thai
MEDICAL ASSOCIATION OF THAILAND
ISSN: 0125-2208 (Print),
ISSN: 2408-1981 (Online)
The content of this site is intended for health professionals.

Submissions

» Online Submissions » Author Guidelines » Copyright Notice » Privacy Statement

Other

» Journal Sponsorship » Site Map » About this Publishing System

© MEDICAL ASSOCIATION OF THAILAND. All Rights Reserved. The content of this site is intended for health professionals.