Suhattaya Boonmak MD*, Polpun Boonmak MD*, Piyaporn Bunsaengjaroen MD*, Somyong Srichaipanha BSc*
Affiliation : * Department of Anesthesiology, Faculty of Medicine, Khon Kaen University, Khon Kaen
Objective : To evaluate disposable LMA for endotracheal intubation using the FOB guidance and blind
techniques.
Materials and Methods : The authors included ASA class I-II patients between 15 and 60 years of age, with
mouth opening more than 3 cm, scheduled for elective surgery. The authors excluded patients with any history
of gastro-esophageal reflux, full stomach or a body weight < 30 kg. All of the patients received standard
general anesthesia. After inducing anesthesia, a disposable LMA No. 3 or No. 4 (Soft Seal(cid:31), Smiths Medical,
Portex Inc, USA) was inserted while the patient was in the sniff position. The authors recorded the insertion
time, the ease of insertion, the anatomic placement and position. The authors then inserted a flexible endotra-
cheal tube (No. 6.5 for LMA No. 4 and No. 6 for LMA No. 3) and recorded the success rate and the ease of
insertion. After three failures, the authors used FOB guidance.
Results : Sixty patients were enrolled (32 males). The mean (cid:31) SD age and BMI was 43.2 (cid:31) 13.4 years and
22.6 (cid:31) 3.9, respectively. Most of the patients had a Mallampati of grade I. The mean (cid:31) SD insertion time was
24.6 (cid:31) 16.1 sec. After the FOB evaluation, only 27 patients had an anatomic placement in full view of the
glottis. Eighteen patients had vocal cords in the middle part of the opening. The success rate of blind endo-
tracheal intubation was 5 percent (95%CI 1.0-13.9) (3/60); while the success rate with FOB guidance was 85
percent (95%CI 73.4-92.9).
Conclusion : A disposable laryngeal mask airway (Soft Seal(cid:31)) for blind endotracheal intubation had a low
success rate, but it could be used more successfully with FOB guidance.
Keywords : Blind endotracheal intubation, Disposable LMA
JOURNAL OF THE MEDICAL ASSOCIATION OF THAILAND
4th Floor, Royal Golden Jubilee Building,
2 Soi Soonvijai, New Petchburi road,
Bangkok 10310, Thailand.
Phone: 0-2716-6102, 0-2716-6962
Fax: 0-2314-6305
Email: editor@jmatonline.com
» Online Submissions » Author Guidelines » Copyright Notice » Privacy Statement
» Journal Sponsorship » Site Map » About this Publishing System
© MEDICAL ASSOCIATION OF THAILAND. All Rights Reserved. The content of this site is intended for health professionals.