Submit manuscript

Accuracy of Endobronchial Ultrasound Guided-Transbronchial Needle Aspiration in Mediastinal Lymph Node Diagnosis

Kittima Bangpattanasiri MD*, Piamlarp Sangsayunh MD* Kanlaya Panjapornpon MD*, Chompunuch Wichitsanguan MD**

Affiliation : * Department of Pulmonary Medicine, Central Chest Institute of Thailand, Nonthaburi, Thailand ** Department of Radiology, Central Chest Institute of Thailand, Nonthaburi, Thailand

Objective : To evaluate the efficacy of Endobronchial ultrasound guided-transbronchial needle aspiration (EBUS-TBNA) for biopsy specimens with adequate evaluable lymphocytes and mediastinal lymph node diagnosis. Material and Method: Prospective cohort study. Over 18 year old patients with mediastinal or hilar lymphadenopathy, with short axis diameter greater than 10 mm on chest CT were indicated to undergo EBUS-TBNA. When a node was detected, an aspiration was performed under ultrasound guided. The primary end point was the percentage of biopsy specimen with adequate evaluable lymphocytes that had been evaluated by cytopathologist. Secondary end point was the percentage of EBUS-TBNA diagnosis result.
Results : 82 patients with mediastinal or hilar lymphadenopathy underwent EBUS-TBNA. Average size of lymph node was 1.57 x 1.49 cm. The overall of the diagnostic accuracy was a percentage of biopsy specimen with adequate evaluable lympho- cytes as 97.7%. For mediastinal lymph node diagnosis, the cytological evaluation demonstrated that the positive for malignancy, atypical or suspicious for malignancy, negative for malignancy and non-diagnosis were 37.2%, 9.3%, 2.3% and 51.2%, respectively. In case of positive for malignancy, non-small cell carcinoma, adenocarcinoma, bronchoalveolar cell carcinoma and small cell carcinoma were found 62.5%, 15.6%, 3.1% and 18.8% , respectively. Additionally, the pathological examination showed that positive for malignancy, atypical or suspicious for malignancy, negative for malignancy and non-diagnosis were found 35.4%, 7.3%, 3.6% and 53.7%, respectively. There were no complications during all of the procedures.
Conclusion : High percentage of biopsy specimen with adequate evaluable lymphocytes can be obtained in EBUS-TBNA. This finding suggested that this method should be considered for mediastinal lymph node diagnosis.

Keywords : Endobronchial ultrasound guided-transbronchial needle aspiration (EBUS-TBNA)


All Articles Download


INFORMATION

Contact info

JOURNAL OF THE MEDICAL ASSOCIATION OF THAILAND
4th Floor, Royal Golden Jubilee Building,
2 Soi Soonvijai, New Petchburi road,
Bangkok 10310, Thailand.
Phone: 0-2716-6102, 0-2716-6962
Fax: 0-2314-6305
Email: editor@jmatonline.com

JMed Assoc Thai
MEDICAL ASSOCIATION OF THAILAND
ISSN: 0125-2208 (Print),
ISSN: 2408-1981 (Online)
The content of this site is intended for health professionals.

Submissions

» Online Submissions » Author Guidelines » Copyright Notice » Privacy Statement

Other

» Journal Sponsorship » Site Map » About this Publishing System

© MEDICAL ASSOCIATION OF THAILAND. All Rights Reserved. The content of this site is intended for health professionals.