Submit manuscript

Assessment of Inter-fraction Target Motion using On-board Imaging System for Prostate Cancer

Wilai Masa-Nga BSc1, Chirapha Tannanonta MS1, Chirasak Khamfongkhruea MSc1,2, Sangutid Thongsawad MSc1,2, Kanyanee Laebua MD1, Nantakan Apiwarodom MD3

Affiliation : 1 Department of Radiation Oncology, Chulabhorn Hospital, HRH Princess Chulabhorn College of Medical Science, Chulabhorn Royal Academy, Bangkok, Thailand 2 Faculty of Medicine and Public Health, HRH Princess Chulabhorn College of Medical Science, Chulabhorn Royal Academy, Bangkok, Thailand 3 Department of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand

Objective : To determine inter-fraction errors from setup and target motion of prostate cancer treated with intensity modulated radiation therapy [IMRT] by using on-board cone beam computed tomography [CBCT]. Materials and Methods: We analyzed retrospective data of on-board CBCT images of 14 prostate cancers over 395 sessions. We performed image matching of CBCT and planning CT, using two methods, prostate soft tissue matching to determine total error (tumor motion and setup error), and bone matching for setup error only. Target motion values were estimated by subtracting setup error from total error. Systematic error of target motion and setup error were calculated from individual mean values.
Results : Inter-fraction errors for target motion were 0.9+0.6 mm (0 to 8 mm), 0.7+0.5 mm (0 to 6 mm), and 0.5+0.3 mm (0 to 6 mm) for vertical [Vrt], longitudinal [Lng], and lateral [Lat] directions, respectively. Inter-fraction of setup errors were 2.7+1.2 mm (0 to 13 mm) for Vrt direction, 2.2+1.0 mm (0 to 8 mm) for Lng, and 2.8+1.6 mm (0 to 14 mm) for Lat.
Conclusion : With bone matching, planning target volume [PTV] margins should be at least 6 mm in all directions. Systematic setup errors are within 3 mm in all directions.

Keywords : Target motion, Setup error, Inter-fraction, Cone-beam CT, Prostate cancer


All Articles Download


INFORMATION

Contact info

JOURNAL OF THE MEDICAL ASSOCIATION OF THAILAND
4th Floor, Royal Golden Jubilee Building,
2 Soi Soonvijai, New Petchburi road,
Bangkok 10310, Thailand.
Phone: 0-2716-6102, 0-2716-6962
Fax: 0-2314-6305
Email: editor@jmatonline.com

JMed Assoc Thai
MEDICAL ASSOCIATION OF THAILAND
ISSN: 0125-2208 (Print),
ISSN: 2408-1981 (Online)
The content of this site is intended for health professionals.

Submissions

» Online Submissions » Author Guidelines » Copyright Notice » Privacy Statement

Other

» Journal Sponsorship » Site Map » About this Publishing System

© MEDICAL ASSOCIATION OF THAILAND. All Rights Reserved. The content of this site is intended for health professionals.