Outcomes of Radiation Dose Reduction Protocol in Electrophysiologic and Cardiac Device Procedures

Narawudt Prasertwitayakij¹, Kultida Lertthanaphol¹, Siriwan Meemajam², Wanwarang Wongcharoen¹, Teerapat Nantsupawat¹

Affiliation : ¹ Division of Cardiology, Department of Internal Medicine, Chiang Mai University, Chiang Mai, Thailand; ² Maharaj Nakorn Chiang Mai Hospital, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand

Background: Exposure to radiation has been demonstrated to be associated with adverse short- and long-term health outcomes.
Objective: To presented outcomes before and after the implementation of a radiation dose reduction protocol in electrophysiologic (EP) and cardiac device procedures.
Materials and Methods: The present study was a retrospective comparative study, conducted at Chiang Mai University Hospital in Thailand using 2017 and 2019 data, including all patients who underwent EP and cardiac implantable electronic device (CIED) procedures. Exclusion criteria involved patients with incomplete radiation dose records. The authors compared fluoroscopic time, radiation exposure, and complication rates before and after the protocol.
Results: Among the 458 cases, with 214 Eps and 244 devices, the mean age was 58 years. For device implantation procedures, there was no significant change in fluoroscopic time as median (P₂₅, P₇₅) before and after protocol implementation were 3.1 (0.4, 5.8) versus 4.4 (1.2,7.6) minutes, respectively (p=0.117). However, there was a decreasing trend in dose area product (DAP) at 242.0 (119.2, 766.0) versus 197.9 (71.5, 494.5) cGy.cm² (p=0.073). The reduction in DAP was more pronounced in cardiac resynchronization therapy (CRT) implantation when comparing 2017 to 2019 were 1,933.6 (1,039.4, 7,683.8) versus 1,074.6 (427.2, 2,890.7) cGy.cm² (p=0.020). In EP procedures, fluoroscopic time significantly decreased from 8.1 (3.0, 14.3) minutes in 2017 to 1.0 (0.0, 3.6) minute in 2019 (p<0.001), accompanied by a significant reduction in exposure dose of 45.0 (10.8, 153.3) versus 1.7 (0.0, 31.6) mGy (p<0.001) and DAP of 1,022.9 (247.2, 2,660.3) versus 38.5 (0.0, 566.9) cGy.cm² (p<0.001). There was no difference in the complication rate between the two periods.
Conclusion: The implementation of the radiation dose reduction protocol resulted in a significant decrease in radiation exposure during EP procedures and showed a trend towards reduction in CIED procedures.

Received 11 April 2024 | Revised 31 July 2024 | Accepted 8 August 2024
DOI: 10.35755/jmedassocthai.2024.10.771-777-825

Keywords : ALARA; Cardiac electrophysiology; Cardiac implantable electronic devices; Fluoroscopy; Radiation exposure


All Articles Download


INFORMATION

Contact info

JOURNAL OF THE MEDICAL ASSOCIATION OF THAILAND
4th Floor, Royal Golden Jubilee Building,
2 Soi Soonvijai, New Petchburi road,
Bangkok 10310, Thailand.
Phone: 0-2716-6102, 0-2716-6962
Fax: 0-2314-6305
Email: editor@jmatonline.com

JMed Assoc Thai
MEDICAL ASSOCIATION OF THAILAND
ISSN: 0125-2208 (Print),
ISSN: 2408-1981 (Online)
The content of this site is intended for health professionals.

Submissions

» Online Submissions » Author Guidelines » Copyright Notice » Privacy Statement

Other

» Journal Sponsorship » Site Map » About this Publishing System

© MEDICAL ASSOCIATION OF THAILAND. All Rights Reserved. The content of this site is intended for health professionals.