Submit manuscript

Camera Housing for Intraoperative Photography

Sarayuth Dumrongwongsiri1, Chalermpong Chatdokmaiprai1

Affiliation : 1 Division of Plastic and Maxillofacial Surgery, Department of Surgery, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand

Background: Intraoperative photography features key aspects of surgical procedures. However, out-field personnel are usually requested to take photos with a surgeon-owned camera, without acknowledgement of correct surgeon-needed perspectives. The present study presented a waterproof camera housing case that could be sterilized and host a camera in surgical field. Surgeons take better photos themselves with shorter time spent.
Objective: To capture good intraoperative photos with a camera housed in a sterile case without any complications.
Materials and Methods: Fifty photos from twenty patients were taken. Two photos were taken per one visual aspect, one in-field photo from the surgeon who owned the camera, applied in the sterile camera housing case (Group 1), another photo from out-field personnel (Group 2). Both photos were shot with the same camera (Nikon P310) and the same settings with a fixed point of focus. Photo quality, time consumed for each photo taken and the out-field personnel’s satisfaction rate for intraoperative photography were compared. The time consumed for application of the camera into the case was also recorded.
Results: The mean application time until the camera was completely sealed was 36.30+5.25 seconds. Photo quality rate, from two blinded raters, was significantly higher in Group 1 (p-value=0.00). Less time consumed for each photo taken was found in Group 1 (p-value=0.00). Out-field personnel’s satisfaction rates were higher when the surgeon took intraoperative photos himself in Group 1 (p-value=0.00). There was no surgical site infectious complication in all patients in the present study.
Conclusion: A sterile camera housing case, adapted from a waterproof case for underwater photography, could be used for intraoperative photography. Then, good intraoperative photos with less time consumed were achieved without any surgical site infections.

doi.org/10.35755/jmedassocthai.2021.S05.00085

Keywords : Camera housing; Intraoperative photography


All Articles Download


INFORMATION

Contact info

JOURNAL OF THE MEDICAL ASSOCIATION OF THAILAND
4th Floor, Royal Golden Jubilee Building,
2 Soi Soonvijai, New Petchburi road,
Bangkok 10310, Thailand.
Phone: 0-2716-6102, 0-2716-6962
Fax: 0-2314-6305
Email: editor@jmatonline.com

JMed Assoc Thai
MEDICAL ASSOCIATION OF THAILAND
ISSN: 0125-2208 (Print),
ISSN: 2408-1981 (Online)
The content of this site is intended for health professionals.

Submissions

» Online Submissions » Author Guidelines » Copyright Notice » Privacy Statement

Other

» Journal Sponsorship » Site Map » About this Publishing System

© MEDICAL ASSOCIATION OF THAILAND. All Rights Reserved. The content of this site is intended for health professionals.