The Comparison of Intrapartum Sonographic Signs and
Digital Examination in Fetus with Cephalic Presentation
Rachaya Moonsri, MD¹, Panyu Panburana, MD¹, Sommart Bumrungphuet, MD¹
Affiliation : ¹ Department of Obstetrics and Gynecology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
Objective: The agreement of fetal head position examined by digital vaginal examination (DVE) and intrapartum sonographic
signs (ISS) in pregnant women during labor.
Materials and Methods: A cross-sectional study was conducted. Two hundred eight-term singleton pregnant women attending labor at Ramathibodi Hospital, Thailand with the fetal cephalic presentation, cervical dilatation of 4 to 8 cm, station –2 or below and no contraindication for DVE were enrolled. The DVE evaluating fetal head position was performed by the third-year obstetrical residents. After DVE, ISS via transabdominal ultrasound for determining fetal head position was obtained immediately by the first researcher. The DVE report and the ultrasonographic images of ISS were recorded separately. The fetal head position based on ISS was designated by the second researcher blinded to the DVE result. The agreement of DVE and ISS for determining fetal head position was analyzed.
Results: Two hundred eight pregnant women were analyzed. The fetal head position detected by DVE was consistent with that of ISS at 41.3% (p<0.001). The most percent agreement was observed in the fetus with left occiput anterior position at 72.7% (p<0.001). The lowest percent agreement was found in the direct occiput posterior at 14.3% (p=0.243). Parity, gestational age, current body mass index, epidural analgesia, cervical effacement, caput succedaneum, molding, and station did not significantly affect the discrepancy between DVE and ISS.
Conclusion: The agreement between DVE and ISS for evaluating the fetal head position was low. The ISS might be considered for evaluating the fetal head position.
Received 26 December 2019 | Revised 21 January 2020 | Accepted 28 January 2020
doi.org/10.35755/jmedassocthai.2020.11.10949
Keywords : Fetal head position, Intrapartum sonographic sign, Digital vaginal examination