Submit manuscript

Comparison of the Accuracy of Combined Three-Dimensional Fractional Thigh Volume with Biparietal Diameter and Two-Dimensional Ultrasonographic Biometry for Estimating Fetal Weight at 37 to 42 Weeks of Gestation†

Suthasinee Mataneedol MD1, Paweena Paliwong MD1

Affiliation : 1 Department of Obstetrics and Gynecology, Bhumibol Adulyadej Hospital, Bangkok, Thailand


Objective : To compare the accuracy between the new equation of combined three-dimensional ultrasonography [3D-US] fractional thigh volume [Tvol] with biparietal diameter [cTvol-BPD] and formula of two-dimensional ultrasonography [2D-US] for estimating fetal weight.
Materials and Methods : The prospective cross sectional study was conducted in 251 singleton pregnancies at 37 to 42 weeks of gestation. Sonographic evaluation was performed within 48 hours before delivery. The fetal biometry was performed using 2D-US, while fractional Tvol was performed using 3D-US. The estimated fetal weight [EFW] was calculated using both Hadlock’s formula and the new equation from the previous study of Tantechasatid; birth weight (grams) = 1,241.285 + 22.908 Tvol + 43.741 BPD. Paired t-test, Pearson’s correlation coef(cid:976)icient and intraclass correlation coef(cid:976)icient [ICC] were used for data analysis.
Results : The mean fetal weight was 3,142.3 grams (SD 387.6). Birth weight calculated from cTvol-BPD and 2D-US were correlated to actual birth weight (r = 0.9 and 0.8, respectively). The mean difference between cTvol-BPD and actual birth weight was 96.6 grams (SD 194.6, p<0.001), meanwhile 2D-US was 98.5 grams (SD 283.9, p<0.001). Birth weight calculated from new equation was more accurate than Hadlock’s formula, ICC 0.8 (95% CI 0.7 to 0.9), p<0.001) and 0.7 (95% CI 0.6 to 0.8, p<0.001), respectively.
Conclusion : The new equation using combined 3D-US fractional Tvol with BPD was more accurate than 2D-US in estimating fetal weight at 37 to 42 weeks of gestation.

Keywords : Fractional thigh volume, 2-D ultrasonographic biometry, Estimated fetal weight


All Articles Download


INFORMATION

Contact info

JOURNAL OF THE MEDICAL ASSOCIATION OF THAILAND
4th Floor, Royal Golden Jubilee Building,
2 Soi Soonvijai, New Petchburi road,
Bangkok 10310, Thailand.
Phone: 0-2716-6102, 0-2716-6962
Fax: 0-2314-6305
Email: editor@jmatonline.com

JMed Assoc Thai
MEDICAL ASSOCIATION OF THAILAND
ISSN: 0125-2208 (Print),
ISSN: 2408-1981 (Online)
The content of this site is intended for health professionals.

Submissions

» Online Submissions » Author Guidelines » Copyright Notice » Privacy Statement

Other

» Journal Sponsorship » Site Map » About this Publishing System

© MEDICAL ASSOCIATION OF THAILAND. All Rights Reserved. The content of this site is intended for health professionals.