The Result of Capsular Tension Ring Implantation during Phacoemulsification for Subluxated Lens

Rossukon Khotcharrat MD*, Nattapong Mekhasingharak MD*

Affiliation : * Department of Ophthalmology, Faculty of Medicine, Naresuan University, Phitsanulok, Thailand


Objective : To determine patient’s visual acuity and complication after phacoemulsification and intraocular lens (IOL) implantation for zonular dialysis by inserting capsular tension ring (CTR) and to assess factors influencing the visual outcome. Material and Method: In-patient and out-patient medical records of patients that underwent phacoemulsification with IOL and CTR implantations between January 1, 2004 and December 31, 2014, were reviewed for preoperative best corrected visual acuity (pre-op BCVA) and post-operative best corrected visual acuity (post-op BCVA), intraoperative and/or post- operative complications, demographic data, and degrees of zonular weakness.
Results : The present study evaluated 45 eyes from 44 patients. The mean age was 63.3±12.8 years. The zonular weakness ranged from 30 to 180 degrees, the predominant weakness was 60 degrees found in 42.2%. Posterior chamber IOL was placed in the bag 97.8% and only 2.2% in the sulcus placement. The mean pre-op BCVA was 1.5±1.0 logMAR. The median post-op BCVA at 1 (n = 40), 6 (n = 29), 12 (n = 21) months were 0.3 (0.2, 0.4), 0.3 (0.2, 0.4), 0.2 (0.1, 0.4) logMAR, respectively. Sixty-seven-point-five percent of the patients achieved post-op BCVA better than 0.3 logMAR at one month, 64.3% at six months, and 62.5% at one year. Corneal edema was the most common complication found in 38.7% (17/44) on the day after the operation due to the difficulty of the operation but improved with in the first week. Decentered IOL was noticed in only 2.3% (1/44). The authors could not find associated factor influencing visual outcome.
Conclusion : CTR insertion is beneficial in lens subluxation, which allowed safe phacoemulsification and successful IOL implantation. The authors had no financial or proprietary interest in the product, method, or material described herein.

Keywords : Capsular Tension Ring, Phacoemulsification, Subluxated lens, Visual outcome


All Articles Download


INFORMATION

Contact info

JOURNAL OF THE MEDICAL ASSOCIATION OF THAILAND
4th Floor, Royal Golden Jubilee Building,
2 Soi Soonvijai, New Petchburi road,
Bangkok 10310, Thailand.
Phone: 0-2716-6102, 0-2716-6962
Fax: 0-2314-6305
Email: editor@jmatonline.com

JMed Assoc Thai
MEDICAL ASSOCIATION OF THAILAND
ISSN: 0125-2208 (Print),
ISSN: 2408-1981 (Online)
The content of this site is intended for health professionals.